I/O jedinice za proširenje - FX3

FX3 I/O jedinice za proširenje Mitsubishi Electric
Proširive jedinice s napajanjem
Specifications FX2N-32ER-ES/UL FX2N-32ET-ESS/UL FX2N-48ER-DS FX2N-48ER-ES/UL FX2N-48ET-DSS FX2N-48ET-ESS/UL
Electrical data
Integrated inputs/outputs 32 48
Power supply AC range (+10 %, -15 %) 100–240 V 100–240 V 100–240 V
Frequency at ACHz 50/60 50/60 50/60
DC range (+20 %, -30 %) 24 V 24 V
Max. input apparent power 35 VA 30 W 45 VA 30 W 45 VA
Inrush current at ON 100 V AC 40 A<5 ms 40 A<5 ms
200 V AC 60 A<5 ms 60 A<5 ms
Allowable momentary power failure time ms 10 5 10 5 10
External service power supply (24 V DC) mA 250 460 460
Power supply int. bus (5 V DC) mA 690
Inputs
Integrated inputs 16 24
Min. current for logical 1 mA 3.5
Max. current for logical 0 mA 1.5
Response time For all extension units of the MELSEC FX2N series: 10 ms (at time of shipment)
Outputs
Integrated outputs 16 24
Output type Relay Transistor (source) Relay Transistor (source)
Switching voltage (max.) Generally for relay version: <264 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current - per output A 2 0.5 2 0.5
- per group* A 8 0.8/1.6 b 8 0.8/1.6 b
Max. switching power - inductive load W 80 12 80 12
Response time ms 10 <0.2 10 <0.2
Life of contacts (switching times) a For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
Mechanical data
Weight kg 0.65 0.85
Dimensions (WxHxD) mm 150x90x87 182x90x87
Order information Art. no. 65568 65569 66633 65571 66634 65572
  1. Not guaranteed by Mitsubishi Electric
  2. 0.8 for 4 per group and 1.6 for 8 per group* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
Proširive jedinice bez napajanja
Specifications FX2N-8ER-ES/UL FX2N-8EX-ES/UL FX2N-8EYR-ES/UL FX2N-8EYT-ESS/UL FX2N-16EX-ES/UL FX2N-16EYR-ES/UL FX2N-16EYT-ESS/UL
Electrical data
Integrated inputs/outputs 8 16
Number of occupied I/O points in the PLC 16 8 16
Power supply All modular extension blocks are supplied by the base unit.
Inputs
Integrated inputs 4 8 16
Min. current for logical 1 mA 3.5 3.5
Max. current for logical 0 mA 1.5 1.5
Response time For all extension blocks of the MELSEC FX2N series: 10 ms (at time of shipment)
Outputs
Integrated outputs 4 8 16
Output type Relay Relay Transistor Relay Transistor (source)
Switching voltage (max.) Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current - per output A 2 2 0.5 2 0.5
- per group A 8 8 0.8 8 1.6
Max. switching power - inductive load VA 80 80 12 80 12
Response time ms 10 <0.2 10 <0.2
Life of contacts (switching times) b For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
Mechanical data
Weight kg 0.2 0.3
Dimensions (WxHxD) mm 43x90x87 40x90x87
Order information Art. no. 166285 166284 166286 166287 65776 65580 65581
  1. This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
  2. Not guaranteed by Mitsubishi ElectricNote: To connect these modules to a FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
Moduli za proširenje bez napajanja
Specifications FX2NC-16EX-T-DS FX2NC-16EYR-T-DS FX2NC-16EX-DS FX2NC-16EYT-DSS FX2NC-32EX-DS FX2NC-32EYT-DSS
Electrical data
Integrated inputs/outputs 16 32
Power supply All modular extension blocks are supplied by the base unit.
Inputs
Integrated inputs 16 16 32
Input current X0 → X7 / X10 →∞ 7/5 7/5 7/5
Min. current for logical 1 X0 → X7/X10 →∞ mA 4.5/3.5 4.5/3.5 4.5/3.5
Max. current for logical 0mA 1.5 1.5 1.5
Isolation Photocoupler isolation between input terminals and PC power for all base units
Response time For all extension units of the MELSEC FX2NC series: 10 ms (at time of shipment), partly adjustable between 0 and 60 ms in 1 ms steps (REFF, FNC51 = 0–60 ms)
Outputs
Integrated outputs 16 16 32
Output type Relay Transistor Transistor
Switching voltage (max.) V Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current - per output A 2 0.1/0.3 a 0.1/0.3 a
- per group* A 4/8 0.8 0.8
Max. switching power - inductive load VA 80 2.4/7.2 b 2.4/7.2 b
- lamp load W 100 0.3/0.9 c 0.3/0.9 c
Response time ms 10 <0.2 <0.2
Life of contacts (switching times) like base unit
Mechanical data
Connection type Removable screw terminal blocks Ribbon cable connector
Weight kg 0.2 0.15 0.2
Dimensions (WxHxD) mm 20.2x90x89 14.6x90x87 26.2x90x87
Order information Art. no. 128152 128153 104503 104504 104505 104506
0.3 A for Y0 to Y1; 0.1 A all others 7.2 W for Y0 to Y3; 2.4 W all others 0.9 W for Y0 to Y3; 0.3 W all others * This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification. Note: These modules can be combined with PLC base units of the FX3GC or FX3UC series!